Lanbao CR30S AC/DC 2-Wire M30 Capacitive Sensor
Lanbao CR30S-AC/DC 2 Wires Series is an M30 plastic cylindrical capacitive proximity sensor for control systems that require a wide 20-250V AC/DC supply range. It combines a PBT housing, AC/DC 2-wire wiring, adjustable sensing distance, and IP67 protection for non-contact detection of solid, liquid, granular, metal, plastic, and fluid targets.
This listing covers CR30SCF10SB and CR30SCN15SB variants with 10mm flush or 15mm non-flush adjustable rated sensing distance. Store variants include normally-open or normally-closed output logic and either fixed 2m PVC cable or E2 M12 connector wiring.
For related Lanbao capacitive sensors, compare the Lanbao CR30S DC Series, Lanbao CR30S-AC 2-Wire Sensor, and Lanbao CR30-AC Metal Sensor. For a smaller plastic housing option, see the Lanbao CR18S Series.
Technical Specifications
| Brand | Lanbao |
|---|---|
| Series | CR30S-AC/DC 2 Wires Series |
| Sensor Type | M30 cylindrical capacitive proximity sensor |
| Wiring Type | AC/DC 2-wire |
| Housing Size | M30 plastic cylindrical housing |
| Housing Material | PBT |
| Mounting Options | Flush or non-flush, depending on selected variant |
| Rated Sensing Distance | 10mm adjustable for CR30SCF10SB variants; 15mm adjustable for CR30SCN15SB variants |
| Assured Operating Distance | 0-8mm for 10mm variants; 0-12mm for 15mm variants |
| Cable-Type Dimensions | M30 x 62mm for flush cable versions; M30 x 74mm for non-flush cable versions |
| Connector-Type Dimensions | M30 x 79mm for flush E2 connector versions; M30 x 91mm for non-flush E2 connector versions |
| Power Supply | 20-250V AC/DC |
| Output Type | AC/DC 2-wire output |
| Output Logic | Normally open or normally closed, depending on selected variant |
| Standard Target | Fe 45 x 45 x 1t reference for M30 versions |
| Switch-Point Offset | <=+/-20% of rated sensing distance reference |
| Hysteresis Range | 3-20% of rated sensing distance reference |
| Repeat Accuracy | <=3% reference |
| Load Current Reference | AC <=300mA; DC <=100mA |
| Residual Voltage Reference | AC <=10V; DC <=8V |
| Current Consumption Reference | AC <=3mA; DC <=1mA |
| Output Indicator | Yellow LED |
| Operating Temperature | -25C to 70C |
| Operating Humidity | 35-95%RH reference |
| Switching Frequency | AC 15Hz; DC 40Hz |
| Voltage Withstand | 1000V AC 50/60Hz for 60s reference |
| Insulation Resistance | >=50MOhm at 500V DC reference |
| Vibration Resistance | 10-50Hz, 1.5mm reference |
| Protection Rating | IP67 |
| Connection Options | 2m PVC cable or E2 M12 connector, depending on selected variant |
| Available Store SKUs | CR30SCF10SBO, CR30SCF10SBC, CR30SCN15SBO, CR30SCN15SBC, plus matching E2 connector versions |
Integration Notes & Hardware Guidance
- Voltage selection: This is an AC/DC 2-wire series for 20-250V AC/DC circuits. Choose it when one sensor family must support both AC and DC supply environments.
- Sensing-distance selection: Choose CR30SCF10 for 10mm flush mounting or CR30SCN15 for 15mm non-flush sensing distance.
- Output logic: Choose SBO normally-open variants or SBC normally-closed variants according to the required signal state.
- Load planning: AC/DC 2-wire sensors have residual voltage and leakage current, so confirm that the connected load or controller input is compatible before wiring.
- Connection choice: Select fixed 2m PVC cable versions for direct wiring or E2 M12 connector versions when quick replacement and standardized cables are preferred.
Packing List
| Item | Qty | Notes |
|---|---|---|
| Lanbao CR30S-AC/DC capacitive proximity sensor | 1 | Selected sensing distance, output logic, and cable or E2 connector variant |
| Original product packaging | 1 | Packaging may vary by shipment batch |
FAQ
Is this an AC-only sensor?
No. This CR30S version is an AC/DC 2-wire capacitive proximity sensor with a 20-250V AC/DC supply range.
What is the difference between CR30S-AC/DC and CR30S-AC?
The CR30S-AC/DC series supports both AC and DC supply environments, while the CR30S-AC series is specified for AC 2-wire use.
What sensing distances are available?
This listing includes 10mm adjustable flush variants and 15mm adjustable non-flush variants.
How do I choose between SBO and SBC variants?
SBO variants are normally open, while SBC variants are normally closed. Choose according to the signal state required by your control circuit.
What should I check before using an AC/DC 2-wire sensor?
Check supply voltage, load current, residual voltage, leakage current, and whether the connected input device supports AC/DC 2-wire proximity sensors.