Lanbao PR30S-DM5 DC M30 Retro-Reflective Sensor
Lanbao PR30S-DM5 Series is an M30 cylindrical retro-reflective photoelectric sensor for DC industrial automation systems. It is designed for 5m non-adjustable detection using a reflector reference, with NPN or PNP output and NO, NC, or NO+NC logic depending on the selected part number.
This listing covers PR30S-DM5 DC variants, including fixed 2m PVC cable versions and E2 M12 connector versions. The series uses an infrared 880nm LED light source, PBT housing, IP67 protection, and 10-30V DC supply for reflector-based object detection across a beam path.
For related Lanbao photoelectric sensors, compare the Lanbao PR30-DM5 Metal DC Series, Lanbao PR30-DM5 AC 2-Wire Series, and Lanbao PR18S-DM3 DC Series. For an M30 diffuse DC option, see the Lanbao PR30S-BC DC Diffuse Series.
Technical Specifications
| Brand | Lanbao |
|---|---|
| Series | PR30S-DM5 Series |
| Sensor Type | M30 cylindrical retro-reflective photoelectric sensor |
| Product Series Reference | Cylindrical DC series with PBT housing |
| Detection Type | Retro reflection |
| Rated Sensing Distance | 5m non-adjustable reference |
| Standard Target | TD-09 reflector reference |
| Light Source | Infrared LED, 880nm |
| Dimensions | M30 x 62mm and M30 x 80mm references, depending on variant structure |
| Output Type | NPN or PNP, depending on selected variant |
| Output Logic | Normally open, normally closed, or NO+NC, depending on selected part number |
| Power Supply | 10-30V DC |
| Target Type | Opaque object interrupting reflector beam path |
| Repeat Accuracy | <5% reference |
| Load Current Reference | <200mA receiver reference |
| Residual Voltage Reference | <2.5V |
| Consumption Current Reference | <=25mA |
| Circuit Protection | Short-circuit, overload, and reverse-polarity protection reference |
| Response Time | <8.2ms |
| Output Indicator | Yellow LED |
| Ambient Temperature | -15C to +55C |
| Ambient Humidity | 35-85%RH, non-condensing |
| Voltage Withstand | 1000V AC 50/60Hz for 60s reference |
| Insulation Resistance | >=50MOhm at 500V DC reference |
| Vibration Resistance | 10-50Hz, 0.5mm reference |
| Protection Rating | IP67 |
| Housing Material | PBT |
| Connection Options | 2m PVC cable or M12 connector, depending on selected variant |
| Available Store SKUs | PR30S-DM5DNO, PR30S-DM5DNC, PR30S-DM5DNR, PR30S-DM5DPO, PR30S-DM5DPC, PR30S-DM5DPR, plus matching E2 M12 connector versions |
Integration Notes & Hardware Guidance
- Power selection: This is a DC photoelectric sensor series, so confirm the controller input and wiring are compatible with 10-30V DC operation.
- Reflector setup: Retro-reflective detection requires correct sensor-to-reflector alignment; use a suitable reflector such as the TD-09 reference when designing the installation.
- Output selection: Match NPN or PNP wiring to the input type of your PLC, controller, counter, or I/O module before ordering.
- Signal logic: Choose DNO normally-open, DNC normally-closed, or DNR NO+NC variants for NPN, and DPO normally-open, DPC normally-closed, or DPR NO+NC variants for PNP.
- Connection selection: Choose fixed cable versions for simple wiring or E2 M12 connector versions when detachable wiring and easier sensor replacement are preferred.
Packing List
| Item | Qty | Notes |
|---|---|---|
| Lanbao PR30S-DM5 photoelectric sensor | 1 | Selected output type, output logic, and cable or E2 connector variant |
| Integrated cable or M12 connector body | 1 | Connection type depends on selected variant |
| Product label and packaging | 1 | Packaging may vary by shipment batch |
| Documentation reference | 1 | Digital or printed documentation may vary by shipment batch |
FAQ
What detection mode does the PR30S-DM5 Series use?
It uses retro-reflective detection, so the sensor works with a reflector and detects objects when the reflected beam is interrupted.
What sensing distance does this series support?
The official rated sensing distance reference is 5m non-adjustable with a TD-09 reflector reference.
How do I choose between NPN and PNP variants?
Select NPN or PNP according to the input type required by your PLC, controller, counter, or I/O module.
How do I choose between cable and E2 versions?
Cable versions use a fixed 2m PVC cable, while E2 versions use an M12 connector for detachable wiring and easier sensor replacement.
Is a reflector required?
Yes. Retro-reflective sensing requires a reflector aligned with the sensor; verify reflector selection and mounting before installation.